Skip to main content

Troubleshooting Screw Compressors

Systematic diagnosis saves time and prevents unnecessary parts replacement. This guide covers common problems and their solutions.

Diagnostic Approach

The 5-Step Method

  1. Define the problem - What exactly is happening?
  2. Gather data - Pressures, temperatures, hours, history
  3. Isolate the cause - Systematic elimination
  4. Correct the problem - Address root cause, not just symptoms
  5. Verify the fix - Confirm normal operation

Key Operating Parameters

ParameterNormal RangeMeasure At
Discharge pressurePer design ±5%Separator tank
Discharge temperature160-200°F (70-95°C)Discharge port
Oil temperature140-180°F (60-82°C)Oil sump/separator
Oil pressure15-30 PSI above dischargeBefore filter
Inlet pressure-0.5 to -2 PSI vacuumInlet filter
Motor ampsPer nameplate ±10%All phases

Common Problems and Solutions

1. Compressor Won't Start

Troubleshooting flowchart:

Won't Start

┌────┴────┐
│ Power? │
└────┬────┘
No │ Yes
↓ │
Check ├──────────────┐
supply│ │
│ ┌────┴────┐
│ │ Control │
│ │ power? │
│ └────┬────┘
│ No │ Yes
│ ↓ │
│ Check ├─────────────┐
│ fuses │ │
│ │ ┌────┴────┐
│ │ │ Safety │
│ │ │ lockout?│
│ │ └────┬────┘
│ │ Yes│ No
│ │ ↓ │
│ │ Check├────→ Motor/
│ │ fault│ starter
│ │ codes│ issue
SymptomPossible CauseSolution
No power indicationMain breaker trippedReset, check for shorts
Control power, no startE-stop engagedRelease and reset
High temperature lockoutCool down, check cooler
Low oil levelAdd oil, check for leaks
Pressure switch faultCheck settings, replace if failed
Motor hums, won't turnSingle-phasingCheck all phases
Seized compressorCheck manually, may need rebuild

2. Low Discharge Pressure

System pressure low

┌────┴────┐
│ Demand │
│ changed?│
└────┬────┘
Yes│ No
↓ │
Normal├──────────────┐
if load│ │
increased│ ┌────┴────┐
│ │ Inlet │
│ │ filter │
│ │ ΔP? │
│ └────┬────┘
│ High │ Normal
│ ↓ │
│ Replace├────→ Check
│ filter │ internal
│ │ issues
SymptomPossible CauseSolution
Gradual declineInlet filter cloggedReplace element
Leaks in systemLeak survey and repair
Worn intake valveInspect/replace valve
Capacity control faultCheck modulation valve
Sudden dropDemand increaseAdd capacity
Major leakEmergency leak check
Pressure switch failureReplace switch
Relief valve openingCheck setting, look for cause

3. High Discharge Temperature

Normal: 160-200°F (70-95°C) above ambient + compression heat

High Temperature

Temperatures above 225°F (107°C) cause oil breakdown and accelerated wear. Above 250°F (121°C) requires immediate shutdown.

CauseIndicatorsSolution
Cooler fouledHigh temp, normal airflowClean cooler fins
Low airflowHigh temp, fan runningCheck fan, clear obstructions
Fan failureHigh temp, fan not runningReplace fan motor/belt
Low oil levelHigh temp, low sight glassAdd oil, check for leaks
Wrong oilRecent oil changeDrain and refill correct oil
Thermal valve stuckOil bypasses coolerReplace thermal valve
High ambientTemp rises with room tempImprove ventilation
Oversized at low loadHot at low demandAdjust cycling or load
Oil flow through thermal valve:

COLD OIL: HOT OIL:
(Bypass cooler) (Through cooler)

┌──────────┐ ┌──────────┐
│ Thermal │ │ Thermal │
────│ ● Open │────→ │ ● Closed│
│ to sump │ ────│ │────→
└─────┬────┘ └─────┬────┘
│ │
╳ Closed ↓
│ ┌────────┐
To Cooler │ Cooler │
└────────┘

4. High Oil Consumption

Normal consumption: 1-2 pints per 1,000 hours

SymptomCauseSolution
Oil in discharge airSeparator element failedReplace element
Overfilled oil sumpDrain to correct level
Scavenge line cloggedClean or replace line
Wrong oil viscosityUse correct oil
Oil leaks visibleGasket/seal failureReplace gaskets/seals
Loose fittingsTighten connections
Rapid level dropSeparator failureInspect and replace
Internal leak to air sideRebuild compressor

Scavenge line function:

                    Separator Tank
┌────────────────┐
│ ░░░░░░░░ │ ← Separator element
│ ░░░░░░░░ │
│ ┌──┴──┐ │
Clean air out ←─┼─┤ │ │
│ └──┬──┘ │
│ │ Scavenge │
│ │ line ────┼──→ Returns oil
│ │ │ to airend
│▓▓▓▓▓▓▓▓▓▓▓▓▓▓▓│ ← Oil level
└────────────────┘

5. Excessive Noise/Vibration

SoundLikely CauseAction
Metallic rattlingLoose componentsInspect, tighten
GrindingBearing failureImmediate shutdown, repair
KnockingLiquid ingestionCheck inlet, dryer, traps
SquealingBelt slippingAdjust/replace belts
PulsationInlet valve issueInspect/repair valve
High-pitched whineGear or bearing wearSchedule rebuild

Vibration analysis reference:

FrequencyTypical Cause
1x RPMImbalance, misalignment
2x RPMMisalignment, looseness
High frequencyBearing defects
RandomCavitation, turbulence

6. Oil in Compressed Air

Beyond separator carryover limit (typically 2-3 ppm):

CauseDiagnosisSolution
Separator element failureVisual inspection, high carryoverReplace element
Minimum pressure valve stuckLow tank pressure at unloadRepair/replace valve
Overfilled oilLevel above maximum markDrain to correct level
Oil foamingEmulsified appearanceCheck for water, change oil
Wrong separatorCheck part numberInstall correct element
Scavenge system faultOil pooling in separatorClear scavenge line

7. Water in Oil

Symptoms: Milky oil appearance, emulsion

CauseSolution
Aftercooler leakPressure test, repair
Operating below dew pointIncrease load or temperature
Condensation during shutdownInstall crankcase heater
Coolant leak (water-cooled)Pressure test heat exchanger

8. Frequent Loading/Unloading (Short Cycling)

Normal cycle time: >30 seconds loaded, >30 seconds unloaded

CauseSolution
Pressure band too narrowWiden load/unload differential
Tank too smallAdd receiver capacity
Large intermittent demandAdd point-of-use storage
Leak in control airCheck and repair
Faulty pressure transducerCalibrate or replace

After Oil Change

ProblemCauseSolution
High temperatureWrong oil typeDrain, flush, correct oil
FoamingIncompatible oils mixedComplete drain and flush
Low pressureOverfilledDrain to correct level
Oil leaksDisturbed sealsRe-torque, replace seals

After Filter Change

ProblemCauseSolution
High ΔPWrong elementVerify part number
Bypass alarmElement not seatedReinstall properly
Oil carryoverSeparator installed wrongCheck orientation

After Major Service

ProblemCauseSolution
Won't build pressureMinimum pressure valve stuckFree or replace
High temperatureAir in oil systemRun to purge air
VibrationComponents not torquedRe-torque to spec

Diagnostic Tools

ToolUse
Infrared thermometerTemperature spot checks
Ultrasonic detectorLeak detection, bearing analysis
Clamp ammeterMotor current verification
Pressure gaugesSystem pressure checks
Oil analysis kitSample collection for lab
Vibration penQuick vibration screening

When to Call for Service

  • Unusual metallic sounds
  • Smoke or burning smell
  • Oil spraying
  • Temperature won't stabilize below limit
  • Vibration suddenly increases
  • Motor trips repeatedly
  • Any safety system activation
Documentation

Keep a log of operating parameters. Trends are more valuable than single readings for predicting problems.