The compressed air distribution system connects the compressor room to points of use. Inadequate design causes pressure drops, condensation, and energy losses.

Network Configurations​

Loop System​

    ┌────────────────────────────────────────┐
│ │
│ ○────○────○────○────○────○────○ │
│ │ │ │
└────┴────────────┬───────────────┴─────┘
│
Compressor
Room
AdvantageDescription
Bidirectional flowAir arrives via two paths
Lower pressure dropFlow splits, lower velocity
RedundancyIf one section blocks, alternative exists
Uniform pressureBalance at all points

Application: Large plants, distributed demand.

Branch System​

               Compressor
Room
│
┌──────────┼──────────┐
│ │ │
○ ○ ○
│ │ │
┌──┴──┐ ┌──┴──┐ ┌──┴──┐
○ ○ ○ ○ ○ ○
AdvantageDescription
Lower initial costLess total piping
Simple to installDirect routes
Easy to expandAdd branches
DisadvantageDescription
Higher pressure dropUnidirectional flow
No redundancyFailure affects entire branch
Variable pressureDistant points have less pressure

Application: Small plants, concentrated demand.

Combined System​

    ┌────────────────────────────────────────┐
│ │
│ ○────○────○────○────○────○────○ │ ← Main loop
│ │ │ │ │ │
└────┴─────────┼──────────────┴────┴─────┘
│
┌──────┼──────┐
○ ○ ○ ← Secondary branches

Combines main loop with branches to specific areas. Optimal for medium and large plants.

Pipe Sizing​

Calculation Factors​

ParameterUnitDescription
Flow (Q)CFM, m³/minMaximum system demand
Pressure (P)PSI, barOperating pressure
Length (L)ft, mTotal distance including fittings
Allowable drop (ΔP)PSI, barMaximum 3% of pressure
Velocity (V)ft/s, m/sMaximum 20 ft/s (6 m/s) in mains
Line TypeMaximum Velocity
Main line20 ft/s (6 m/s)
Distribution line30 ft/s (9 m/s)
Service line50 ft/s (15 m/s)
Excessive Velocity

Velocities above recommendations cause:

  • Higher pressure drop
  • Excessive noise
  • Erosion at elbows and fittings
  • Condensate entrainment

Quick Sizing Table​

Based on: 100 PSI, 3% drop, 100 ft length

Flow (CFM)Minimum Diameter
101/2"
253/4"
501"
1001-1/4"
2001-1/2"
4002"
7502-1/2"
1,0003"
2,0004"
4,0006"

For longer lengths: Increase one size for each doubling of length.

Equivalent Length of Fittings​

Fittings add flow resistance. Expressed as equivalent length of straight pipe:

FittingEquivalent Length (in diameters)
90° standard elbow30 D
90° long radius elbow20 D
45° elbow16 D
Tee (straight flow)20 D
Tee (90° flow)60 D
Ball valve (open)3 D
Gate valve (open)8 D
Globe valve (open)340 D
Swing check valve100 D
Reducer10 D
Expander25 D

Example: A 90° elbow in 2" pipe equals 30 × 2" = 60" = 5 ft of straight pipe.

Piping Materials​

Material Comparison​

MaterialMax PressureMax TempCorrosion ResistanceRelative Cost
Black steel300+ PSI400°FLow$
Galvanized steel300+ PSI400°FMedium$$
Copper type L250 PSI400°FHigh$$$
Aluminum200 PSI150°FHigh$$$$
Stainless steel300+ PSI400°FVery high$$$$$
PVC/CPVCSee noteSee noteHigh$
PVC/CPVC

PVC and CPVC are NOT approved for compressed air per OSHA. They can fail catastrophically due to:

  • Cyclic pressure fatigue
  • UV degradation
  • Impact
  • Oil contact

Only use plastic systems specifically designed and certified for compressed air.

Black Steel (Schedule 40)​

AdvantageDisadvantage
EconomicalInternal corrosion
High pressureScale contaminates air
Easy to sourceRequires exterior paint
WeldableHeavy

Use: Main lines, limited budget.

Extruded Aluminum​

AdvantageDisadvantage
No corrosionLower max pressure
LightweightHigh initial cost
Quick connectionsRequires special tools
Smooth interiorLimited to 150°F
Modular

Use: New installations, plants requiring frequent modifications.

Copper Type L​

AdvantageDisadvantage
No corrosionHigh cost
Decades of proven useRequires brazing
Smooth interiorConnections take time

Use: Permanent installations, instrument air.

Installation​

Slope​

All horizontal lines must slope toward drain points:

    Compressor                              Drain
○━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━◇
↘ 1-2% slope ↘
SlopeApplication
1% (1/8" per foot)Minimum acceptable
2% (1/4" per foot)Recommended

Drain Points​

Install at:

  • Low points in the network
  • Before regulators
  • Before critical equipment
  • End of dead-end lines
  • Every 100-150 ft in main lines
    Main line
━━━━━━━━━━━━━━━━━━━━━━━
│
│ Drop leg
│ (pocket)
▼
┌───┐
│ D │ ← Automatic drain
└───┘

Air Takeoffs​

Connection to equipment should be from the top of the pipe:

    CORRECT:               INCORRECT:

○ ← Takeoff ━━━━━━━━━
━━━━━┿━━━━━ │
│ ○ ← Collects
↓ condensate
Equipment and dirt

Supports​

DiameterMaximum Support Spacing
1/2" - 1"6-8 ft (2-2.5 m)
1-1/4" - 2"8-10 ft (2.5-3 m)
2-1/2" - 4"10-12 ft (3-3.5 m)
6" and larger12-15 ft (3.5-4.5 m)

Acceptable Pressure Drop​

Pressure Drop Budget Distribution​

ComponentMaximum Drop
Aftercooler3 PSI (0.2 bar)
Dryer3-5 PSI (0.2-0.35 bar)
Filters3-5 PSI (0.2-0.35 bar)
Main piping1-2 PSI (0.07-0.14 bar)
Distribution piping1-2 PSI (0.07-0.14 bar)
Point of use FRL5-10 PSI (0.35-0.7 bar)
Total system15-25 PSI (1-1.7 bar)

Cost of Pressure Drop​

For every 2 PSI of additional system drop, approximately 1% more compressor energy is required.

Extra DropEnergy IncreaseAnnual Cost*
5 PSI2.5%$625
10 PSI5%$1,250
15 PSI7.5%$1,875
20 PSI10%$2,500

*Based on 100 HP compressor, $0.10/kWh, 8,000 h/year